-40%

2021 KIG ColdRush 6 ton Dual Circuit Air Cooled Glycol Chiller 230V 3p 86 gal

$ 5227.2

Availability: 100 in stock
  • Brand: KIG Coldrush
  • Refrigerant: R-410a
  • All returns accepted: ReturnsNotAccepted
  • BTU Cooling Rating: 72,000 btu's/hr nominal
  • Power Phase: 3 Phase
  • Tank Capacity: 86 gallon
  • Cooling Capacity: 72,000 btu's / hr nominal
  • Components: Compressor
  • Features: Auto-Shut off Valve
  • Supply Voltage: 230 V
  • Item Width: 40
  • Compressor Type: Scroll (dual)
  • Item Length: 72
  • Condition: New

    Description

    New, USA made 6 hp / ton Glycol (or water) Air Cooled Chiller. This is a USA made chiller with reservoir tank and centrifugal pump. Chill and pump your glycol solution down to 25°F temperatrue.   This Dual Circuit unit is very popular with brewers, but equally as fine for warmer fluid temps and other industrial applications.  This chiller is a "TRUE" Dual Circuit Chiller - it's almost like two separate 3 hp chillers side by side, sharing a common tank and pump.  So, two compressors, two condensers, two evaporators, two sets of three of adjustable pressure switches (low / hi / fan) for SIX total.  It's the ultimate in redundancy for optimum uptime.    This unit is either in stock, or being made for stock.  Please communicate with use to confirm lead time.  Power is 208/230 THREE phase power.
    Please see our other listings.  These KIG ColdRush Chillers are made in 2, 3, 4, 5, 6, 8, and 10 ton, in both single and three phase power.  We almost always have these sizes in stock, or in process of being made for stock.   5 ton and smaller are single circuit units.  The 6, 8, and 10 ton models are the DUAL design.
    *** Photos may be of similar size units, and with covers (included) off to show inside. Many configurations are made, and exact appearance and components placement may change from model to model. ***  Let us know if any questions at all, Chillers are ALL WE DO.
    Model KIG ColdRush GV72CK3-DCRLT
    Latest R410a refrigerant.
    Dual Fan type condenser
    72,000 btu/hr at 55F nominal fluid temps
    ~36,000 btu/hr at 28F glycol fluid temps
    This unit is 208/230 volt, THREE phase power - Ampacity 33 / Max Fuse 43 amps
    Limit devices: high / low refrigerant, and LOW ambient fan switching (3 per circuit)
    Outdoor RATED for -20°F to 130°F extreme ambient and weather conditions.  Fine for indoors too.
    Stainless INSULATED Tank: 86 gallons.
    Tanks is of SEALED type with vent - NO need to worry about "flow back" to unit when power off
    Glycol level sensor with alarm/light
    Dual Stage Ranco Temperature Controller - Easy set up to run of just one compressor, or 2, as demand requires.
    1.5 hp process pump (capable of up to 47 gpm/49 psi nominal)
    Internal fixed glycol flow bypass - no need to add bypass valve in your piping loop.
    No freeze coil type evaporator / exchanger (DUAL) within stainless tank.  No pump energy or flow pressure is consumed or required by this evaporator configuration (in contrast to plate style heat exchangers).  0 psi flow return back to chiller is fine, this is a super efficient configuration.
    1 Year Warranty
    USA Made
    Approx 40" wide x 72" long x 60" tall
    Fully Crated
    Customer Service Location:
    Keith Industrial Group, Inc.
    104 Sterling St., Ste. R
    Clinton, MA 01510  USA